Standard Heat Pump (5F) Emura Wall Mounted (Silver)
0.75 to 1.5 Tons | Model: RX_W + FTXR_W_S
***Warning: Transitioning to R-32***
| Heating Capacities (BTU/HR) | Piping | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Model Number | Nominal Size (MBH) | Indoor Unit CFM (High/Medium/Low/Super Low) | Nominal Cooling @95°F (BTU/HR) | 43°FWB | 5°FWB | Lineset Size | Max Total Length (ft) | Max Vertical Length (ft) | Energy Star Certified |
| FTXR09WVJUS9 + RX09WMVJU9 | 9 | 346 / 258 / 201 / 117 | 10,600 | 14,600 | 4,480 | 1/4" x 3/8" | 66 | 49 | No |
| FTXR12WVJUS9 + RX12WMVJU9 | 12 | 395 / 290 / 226 / 131 | 12,800 | 15,800 | 6,040 | 1/4" x 3/8" | 66 | 49 | No |
| FTXR18WVJUS9 + RX18WMVJU9 | 18 | 413 / 332 / 275 / 208 | 18,500 | 21,200 | 8,970 | 1/4" x 1/2" | 98 | 66 | No |
Features
- Intelligent eye operation
- Colored LED indication light on wall mount
- 5 selectable fan speeds with Quiet and Auto
- 3-D airflow control with horizontal and vertical flaps
- Titanium Apatite Photocatalytic Air Purifying Filter
- Auto restart after power failure (reinstates previous settings)
- Powerful and ECO+ modes
- Hydrophilic blue fin coating of indoor unit for enhanced coil cleanliness and lifespan
- Options for gravity drained condensate or field installed condensate pump that fits within the unit cabinet.
Electrical Information
| MCA (A) / MOP (A) | ||||
|---|---|---|---|---|
| Type | Voltage | 9 MBH | 12 MBH | 18 MBH |
| Outdoor unit | 208-230V/1ph | 13 / 15 | 9.1 / 15 | 12.8 / 15 |